FRONIUS STATE CODES

If your Fronius unit displays an error code please check below as to what that code means.

CODEDescriptionBehaviorRemedy
STATE 102AC voltage too highFollowing careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
STATE 103AC voltage too lowFollowing careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
STATE 105AC frequency too highFollowing careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
STATE 106AC frequency too lowFollowing careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
STATE 107AC frequency too lowFollowing careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
STATE 108Stand alone operation detectedFollowing careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
STATE 112RCMU errorFollowing careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. Check grid connections: If this STATE code keeps recurring contact your solar power system installer.
---------------------------------3xx------------------------------------------------------------------------------------------------------------------------------------------------------------
STATE 301Over current (AC)Short-term interruption while feeding energy into the grid due to over current in the inverter. The inverter resumes with its startup routine.
Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner.
STATE 302Over current (DC)Short-term interruption while feeding energy into the grid due to over current in the inverter. The inverter resumes with its startup routine.
Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner.
STATE 303Power stage set over temperatureShort-term interruption while feeding energy into the grid due to over temperature in the inverter. The inverter resumes with its startup routine.
Purge openings for cooling air and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer
STATE 304Internal temperature too highShort-term interruption while feeding energy into the grid due to over temperature in the inverter. The inverter resumes with its startup routine.
Purge openings for cooling air and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer
STATE 306LOW PV OUTPUT Intermediate circuit voltage too low for feeding energy into the gridShort term interruption while feeding energy into the grid. The inverter resumes with its startup routineFault is rectified automatically; if this STATE code occurs when there is sufficient sunlight, contact your solar power system installer. IMPORTANT! Due to the low level of sunlight early in the morning and evening, the STATE code 306 (LOW PV OUTPUT) & 307 (LOW PV VOLTAGE) are displayed routinely at these times of the day. These STATE codes do not indicate any kind of fault.
STATE 307LOW PV VOLTAGE DC input voltage too low for feeding energy into the gridShort term interruption while feeding energy into the grid. The inverter resumes with its startup routineFault is rectified automatically; if this STATE code occurs when there is sufficient sunlight, contact your solar power system installer. IMPORTANT! Due to the low level of sunlight early in the morning and evening, the STATE code 306 (LOW PV OUTPUT) & 307 (LOW PV VOLTAGE) are displayed routinely at these times of the day. These STATE codes do not indicate any kind of fault.
STATE 308Intermediate circuit overvoltageShort term interruption while feeding energy into the gridFault is rectified automatically; if this STATE code is displayed all the time; notify your local Fronius Service Partner
STATE 309DC input voltage MMPT 1 too highShort term interruption while feeding energy into the gridFault is rectified automatically; if this STATE code is displayed all the time; notify your local Fronius Service Partner
STATE 313DC input voltage MMPT 2 too highShort term interruption while feeding energy into the gridFault is rectified automatically; if this STATE code is displayed all the time; notify your local Fronius Service Partner
STATE 318Reverse DC currentSolar module return current detectedIf the STATE code is displayed all the time, contact your local Fronius Service Partner
---------------------------------4xx-----------------------------------------------------------------------------------------------------------------------------------------------------------
STATE 401No communication with power stage set possibleThe inverter will automatically attempt to connect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 406Power stage set temperature sensor faultyThe inverter will automatically attempt to connect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 407Internal temperature sensor faultyThe inverter will automatically attempt to connect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 408DC feeding into the grid detectedThe inverter will automatically attempt to connect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 412Fixed voltage mode has been selected instead of MPP voltage mode and the fixed voltage has been set too low or too high a valueIf this STATE code persists contact your local solar power installer
STATE 415Safety cut out via option card or RECERBO has triggeredThe inverter is not feeding any energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 416No communication possible between power stage set and control systemThe inverter will automatically attempt to reconnect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 417Hardware ID problemThe inverter will automatically attempt to reconnect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 419Unique ID conflictThe inverter will automatically attempt to reconnect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 421HID range errorThe inverter will automatically attempt to reconnect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 425No communication possible with the power stage setThe inverter will automatically attempt to reconnect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 426 - 428Possible hardware faultThe inverter will automatically attempt to reconnect again and if possible will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 431Software problemThe inverter is not feeding energy into the gridCarry out an AC reset (switch the AC circuit breaker off and on); update the firmware; if this STATE code is displayed all the time, please contact you local Fronius Service Partner
STATE 436Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, eg. after a PC board has been replaced.)The inverter will automatically attempt to connect again and if possible will resume feeding energy into the gridUpdate the inverter firmware; if this STATE code is displayed all the time, please contact your local Fronius Service Partner
STATE 437Power stage set problemThe inverter will automatically attempt to connect again and if possible will resume feeding energy into the gridUpdate the inverter firmware; if this STATE code is displayed all the time, please contact your local Fronius Service Partner
STATE 438Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, eg. after a PC board has been replaced.)The inverter will automatically attempt to connect again and if possible will resume feeding energy into the gridUpdate the inverter firmware; if this STATE code is displayed all the time, please contact your local Fronius Service Partner
STATE 443Intermediate circuit voltage too low or asymmetricThe inverter is not feeding any energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 445Invalid limit value settingsThe inverter is not feeing any energy into the grid for safety reasonsUpdate the inverter firmware with the latest firmware; if the STATE code is displayed all the time after firmware update, contact your local Fronius Service Partner
STATE 447Insulation faultThe inverter is not feeing any energy into the grid for safety reasonsIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 448Neutral conductor not connectedThe inverter is not feeing any energy into the grid for safety reasonsIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 450Guard cannot be foundThe inverter is not feeing any energy into the grid for safety reasonsIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 451Memory error detectedThe inverter will automatically attempt to connect again and if possible, will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 452Communication error between the processorsThe inverter will automatically attempt to connect again and if possible, will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 453Short term grid voltage errorThe inverter will automatically attempt to connect again and if possible, will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 454Short term grid frequency errorThe inverter will automatically attempt to connect again and if possible, will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 456Anti-islanding function is no longer implemented correctlyThe inverter will automatically attempt to connect again and if possible, will resume feeding energy into the gridIf the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 457Grid relay stickingThe inverter is not feeding any energy into the gridContact you local Fronius Service Partner
STATE 459Error when recording the measuring signal for the insulation testThe inverter is not feeding any energy into the gridContact you local Fronius Service Partner
STATE 460Reference voltage source for the digital signal processor (DSP) is working out of toleranceThe inverter is not feeding any energy into the gridContact you local Fronius Service Partner
STATE 461Fault in the DSP data memoryThe inverter is not feeding any energy into the gridContact you local Fronius Service Partner
STATE 462Error with DC feed monitoring routineThe inverter is not feeding any energy into the gridContact you local Fronius Service Partner
STATE 463Reversed AC polarity, AC connector inserted incorrectlyThe inverter is not feeding any energy into the gridContact you local Fronius Service Partner
STATE 474RCMU sensor faultyThe inverter is not feeding any energy into the gridContact you local Fronius Service Partner
STATE 475Solar panel ground fault, insulation fault (connection between solar panel and ground)The inverter is not feeding any energy into the gridContact you local Fronius Service Partner
STATE 476Driver supply voltage too lowThe inverter is not feeding any energy into the gridIf the State code keeps recurring, contact your local Fronius Service Partner
STATE 480 & 481Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, eg. after a PC board have been replaced)The inverter is not feeding any energy into the gridUpdate the inverter firmware with the latest firmware; if the STATE code persist, contact your local Fronius Service Partner
STATE 482Startup incompleteThe inverter is not feeding any energy into the gridPerform AC reset (turn AC circuit breaker off and on), complete startup
STATE 483Voltage UDC fixed on MPPT 2 string out of limitsThe inverter is not feeding any energy into the gridCheck the MPP settings; if the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 485CAN transmit buffer is fullThe inverter is not feeding any energy into the gridCarry out an AC reset (turn AC circuit breaker off and on), if the STATE code continues to be displayed, notify your local Fronius Service Partner
---------------------------------5xx------------------------------------------------------------------------------------------------------------------------------------------------------------
STATE 502Insulation errorWarning message is shown on the displayIf this STATE code keeps recurring, contact your solar power system installer
STATE 509No energy fed into the grid in the past 24 hoursWarning message is shown on the displayAcknowledge STATE code; check weather all the conditions for the problem are free feeding of energy into the grid have been met. If the STATE code is displayed all he time; look out for further STATE codes
STATE 515No communication with filter possibleWarning message is shown on the displayIf the STATE code is displayed all the time, notify your local Fronius Service Partner
STATE 516No communication with the storage unitWarning message is shown on the displayIf the STATE code is displayed all the time, notify your local Fronius Service Partner
STATE 517Derating caused by too high a temperatureWhen power derating occurs, a warning message is shown on the displayPurge cooling air openings and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring, contact your solar power system installer
STATE 522DC1 input voltage too lowThe DC voltage on input 1 of the inverter is too lowCheck voltage & polarity on input 1 of the inverter. If this STATE code keeps recurring, please contact your solar power system installer
STATE 523DC2 input voltage too lowThe DC voltage on input 2 of the inverter is too lowCheck voltage & polarity on input 2 of the inverter. Check MPP settings/voltage at the "Installer Menu Basic". If this STATE code keeps recurring, please contact you solar power system installer
STATE 558Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, EG. after a PC board have been replaced)Possible error displays or malfunction on the inverterIf this STATE code keeps recurring, contact your solar power system installer
STATE 560Derating caused by over-frequencyThis STATE code is display when the grid frequency becomes excessively high. The inverter will then reduce its output. The status indicator will continue to be displayed until the inverter has returned to normal operationAs soon as the grid frequency is back within the permissible range and the inverter has returned to normal operation, the fault is rectified automatically. If this STATE code keeps recurring, contact your solar power system installer
STATE 566Arc detector switched off (eg. during external arc monitoring)The STATE code is displayed every day until the are detector is reactivatedNo error, Confirm STATE code by pressing "ENTER"
STATE 567Grid Voltage Dependent Power Reduction is activeThis STATE code is a warning informing you that the Grid Voltage Dependent Power Reduction mode (GVDPR or Volt - Watt mode) has been activated and the inverter will continue to operate with reduced power output. This is because the grid voltage has exceeded 250Vac and the GVDPR has been enabled to try reduce the voltage rise at the inverters terminals. This mode must be enabled by default in accordance with the Australian Standards.Acknowledge STATE code; if this STATE code keeps recurring, contact you local solar power system installer
---------------------------------7xx------------------------------------------------------------
STATE 705Conflict when setting the inverter number (eg. number already assigned)Correct the inverter number via the setup menu
STATE 721EEPROM has been reinitialised or EEPROM is faultyWarning message is shown on the displayAcknowledge STATE code; If the STATE code is displayed all the time, contact you local Fronius Service Partner
STATE 731Initialisation error - USB stick is no supportedWarning message is shown on the displayCheck or replace USB stick. Check the file system on the USB stick. If the STATE code is displayed all the time, notify your local Fronius Service Partner
STATE 732Over current on USB stickWarning message is shown on the displayCheck or replace USB stick. Check the file system on the USB stick. If the STATE code is displayed all the time, notify your local Fronius Service Partner
STATE 733No USB stick connectedWarning message is shown on the displayConnect or check the USB stick. If STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 734Update file not recognised or not presentWarning message is shown on the displayCheck update file (eg. for correct file name). If STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 735Update file does not match the device, update file too oldWarning message appears on the display, update process is interruptedUpdate the inverter firmware; if the STATE code is displayed all the time after the firmware update, contact your local Fronius Service Partner
STATE 736Write or read error occurredWarning message is shown on the displayCheck USB stick and the data contained on it or replace USB stick. Never unplug a USB stick if the 'Data Transmission' LED is still flashing or lit. If the STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 738Log file cannot be saved (eg. USB stick is write protected or full)Warning message is shown on the displayCreate storage space, remove write protection, check or replace USB stick if necessary. If STATE code is displayed all the time, contact you local Fronius Service Partner
STATE 743Error occurred during update processWarning message is shown on the displayRepeat the update process, check USB stick. If STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 745Update file corruptWaring message appears on the display, update process is interruptedRedownload the latest firmware. If STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 751Time lostWarning message is shown on the displayReset the time and date on the inverter. Check update file (eg. for correct file name). If STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 752Real Time Clock module communication errorWarning message is shown on the displayReset the time and date on the inverter. Check update file (eg. for correct file name). If STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 757Hardware error in the Real Time Clock moduleError message is shown in the display, the inverter is not feeding any energy into the gridIf STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 758Internal error; Real Time Clock module is in emergency modeTime may be inaccurate or lost (feeding energy into the grid normal)If STATE code is displayed all the time, contact your local Fronius Service Partner
STATE 766Emergency power derating has been activatedError message shown in the displayIf STATE code is displayed all the time, contact your local Fronius Service Partner